Events: ISDN PRI (E1)
|
Event Structure |
What is ISDN PRI E1 physical event ?... |
|
|
PH decoding |
by using Clarinet Event-Editor with a
filter ... |
|
|
Protocol stack |
Which protocol specifications to be
defined in the current filter ?... |
|
|
Standards |
- ITU Recommendation G703, G704
|
|
|
Options |
Changing the display conditions in the
current filter ?... |
|
ISDN PRI E1 event decoding
|
<alarm i>
|
Alarm or info_bit state evolution in the
following format: xydesignation |
|
xy
|
++ |
ON state stable (no transition) |
-- |
OFF state stable (no transition) |
+- |
transition from the ON state to the OFF state |
-+ |
transition from the OFF state to the ON state |
|
|
designation
|
FL |
loss of frame alignment |
PVT in french |
ALM |
alarm indication to the remote end |
PVTd in french |
AIS |
alarm indication signal (2 Mbits) |
SIA in french |
CRC |
CRC multi-frame alignment |
|
AIS64K |
alarm indication signal (TS 16) |
|
Sa7 |
Sa7 bit of TS0 |
|
MFL |
loss of multi-frame alignment (abcd signalling). |
PVMT in french |
ALM |
alarm indication to the remote end (abcd signalling) |
PVMTd in french |
|
|
<error_string> |
- CRC error (multi-frame CRC4 value)
- Clock slip
|
Native ISDN PRI (E1) physical event
The ISDN PRI (E1) physical events are generated by the analysis process on
the PH link when the physical interface type is based on ISDN PRI (E1 Trunk):
- Every transition of state of the physical interface (frame alarm,
multiframe alarm, info bit) generates an event.
- Additional events can be generated upon detection of a clock slip or an
errored CRC4 value.
The binary event structure is defined in the Clarinet-API.
The edition of the ISDN PRI (E1) physical events without any
decoding/formatting allows to display the successive states of the physical
interface.
|