FR Simulator - management of callsThe purpose of the FR call simulator is to manage virtual connections (switched SVC or permanent PVC) using the Data link and to sequence data frames transfers. The FR call simulator uses the level 2 and level 3 emulator services provided by the AS-INTERFACE. Protocol simulation: behaviourThe virtual calls are:
The FR call simulator can use different link types:
For each link, the simulator allows to generate automatically up to 50
outgoing calls specified individually and to accept up to 99 incoming calls. The
total number of virtual circuits simultaneously established can be 100 (50
outgoing calls whilst accepting 50 incoming calls).
Protocol emulation: rules of protocolThe Layer 2 and Layer 3 emulators are initialized by the choice of the protocol used (CCITT Q933, FRF.4 or T1.617) and the operating options (set of parameters).
|
home Quick start Specifications Connections Features How to? Notes Search Site Map updated: 27-Feb-04 |