ISDN Simulator - emulator dialing process

 

The process of dialing number in overlap mode is done with the following operating rules:

  • the T302 timer is set at each INFORMATION message reception.
  • the dialing is finished when one of the following conditions is verified:
    • the Sending complete IE (or # character of Called party number IE) is received.
    • the number of digits reaches the maximum value before the expiry of T302.
    • the T302 timer is out.
  • the complete dialing number is processed as:
    • a correct value if the number of digits is equal or more than the minimum value.
    • an incorrect value if the number of digits is less than the minimum value.

In the NUMERIS French version:

  • minimum value= value of RCMI parameter.
  • maximum value= value of RCMA parameter.

When minimum and maximum number criteria are not used, the values are set to the limits described in relevant numbering plan.

 


home     Quick start     Specifications     Connections     Features     How to?     Notes     Search     Site Map

updated:  27-Feb-04