How to aggregate TS's over an E1/T1 TrunkClarinet-system supports the monitoring and simulation on a group of Time-Slots of a E1 or T1 interface:
Connecting the unitSee the pictures in the 'How to connect E1/T1 interface to Clarinet-Book USB' page. Setting the test conditions for BOP monitoringA new profile can be created with the Wizard from the Template list by selecting:
Profile resulting from the wizard is ready for BOP monitoring over the B channel #1. Example: Modifications to monitor Frame-Relay over 4 TS'sThe TS's are supposed to be the 2, 4, 5, 6 for an aggregated Data Link at 256 kbit/s. In the profile access to Interface-Spec... ->Data Link and select:
Warning: any number and value of TS can be selected but the same number of TS's must be selected in TD and RD. Setting the test conditions for BERT simulationA new profile can be created with the Wizard from the Template list by selecting:
Profile resulting from the wizard is ready for Bert Simulation over the B channel #1. When Running the profile, the Bert Measurement has to be launched through Manual commands:
Example: Modifications to simulate BERT over 30 TS's of E1(The TS's are supposed to be (1-15 + 17-31) for an aggregated Data Link at 1920 kbit/s. In the profile access to Interface-Spec... ->Data Link :
|
home Quick start Specifications Connections Features How to? Notes Search Site Map updated: 27-Feb-04 |