SS7 - ITU-SCCP protocol

The following table provides a summary of the SCCP messages structure included in this page:

Message format ITU-Q713 arrow_2_forward.gif (1040 octets)
List of  Messages types. ITU-Q713 arrow_2_forward.gif (1040 octets)
List of  messages Parameters ITU-Q713 arrow_2_forward.gif (1040 octets)
List of time-limits ITU-Q713 arrow_2_forward.gif (1040 octets)
List of Primitives of Service ITU-Q713 arrow_2_forward.gif (1040 octets)

SCCP: Message format

Octets 1-4: Label
bits 14-1 DPC: Destination Point Code
bits 28-15 OPC: Origine Point Code
bits 32-29 SLS: Signalling Link Selection
Octets 5-6: CIC
bits 8-1 Circuit Identification Code (8 LSB)
Octet 5: Message type code
bits 8-1 Type
Octets 6-l: Mandatory fixed part
  Parameter A
  Parameter ...
  Parameter F
Octets m-p: Mandatory variable part
  Pointer to parameter M
  Pointer to parameter ...
  Pointer to parameter P
  Pointer to start of optional part
  Length indicator of parameter M
  Parameter M
  ...
  Length indicator of parameter P
  Parameter P
Octets q-z: Optional part
  Parameter name=X
  Length indicator of parameter X
  Parameter X
  ...
  Parameter name=Z
  Length indicator of parameter Z
  Parameter Z
  End of optional parameters

SCCP: List of messages

Sorted by codes

Sorted by Type

Code Type Signalling Connection Control Part
01 CR Connection Request
02 CC Connection Confirm
03 CREF Connection Refused
04 RLSD Released
05 RLC Released Complete
06 DT1 Data Type 1
07 DT2 Data Type 2
08 AK Data Acknowledgement
09 UDT Unit Data
0A UDTS Unit Data Service
0B ED Expedited Data
0C EA Expedited Data Acknowledgement
0D RSR Reset Request
0E RSC Reset Confirm
0F ERR PDU Error
10 IT Inactivity Test

Type Code Signalling Connection Control Part
AK 08 Data Acknowledgement
CC 02 Connection Confirm
CR 01 Connection Request
CREF 03 Connection Refused
DT1 06 Data Type 1
DT2 07 Data Type 2
EA 0C Expedited Data Acknowledgement
ED 0b Expedited Data
ERR 0F PDU Error
IT 10 Inactivity Test
RLC 05 Released Complete
RLSD 04 Released
RSC 0E Reset Confirm
RSR 0D Reset Request
UDT 09 Unit Data
UDTS 0A Unit Data Service

SCCP: List of parameters

Sorted by hex. codes

Sorted by designations

Hexa SCCP Parameters type
00 End of optional parameters
01 Destination local reference
02 Source local reference
03 Called party address
04 Calling party address
05 Protocol class
06 Segmenting/reassembling
07 Receive sequence number
08 Sequencing/segmenting
09 Credit
0A Release cause
0B Return cause
0C Reset cause
0D Error cause
0E Refusal cause
0F Data
Hexa SCCP Parameters type
03 Called party address
04 Calling party address
09 Credit
0F Data
01 Destination local reference
00 End of optional parameters
0D Error cause
05 Protocol class
07 Receive sequence number
0E Refusal cause
0A Release cause
0C Reset cause
0B Return cause
06 Segmenting/reassembling
08 Sequencing/segmenting
02 Source local reference

SCCP:  List of time-limits

Timer

Value Designation
T1    
T1*    

SCCP: List of primitives

  Primitives
   

 

 


home     Quick start     Specifications     Connections     Features     How to?     Notes     Search     Site Map