ATM signalling behaviour: Responder default data source
The type of the selecting conditions listed in the left-side area depends on
the by IE selection.
- No. A selection between several sources is possible
according to conditions defined on the called number of incoming the call.
- Yes.
A selection between several sources is possible
according to whether an IE with a particular content is present in the SETUP message of
the incoming call.
Called number condition
The Called number conditions are
checked in the order of definition of the lines and the source corresponding to the first
satisfied condition is connected.
- an empty condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the Called number conditions.
If called number
of incoming call is: The Called number,
included in the signalling of the incoming communication, defines the connection
condition of the data source defined on the same line.
then,
Connect data source.
Active source used for the incoming communication
if the called number defined on the same line matches the received called number.
None. (No source is connected) is the only choice.
IE condition
The IE conditions are checked in the
order of definition of the lines and the source corresponding to the first satisfied
condition is connected.
- an Any IE condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the IE conditions.
If IE present in incoming
SETUP: The IE precisely specified and
included in the SETUP message of the incoming communication defines the connection
condition of the data source defined on the same line.
The highlighted IE is the current one, which can be selected from a choice list, or
used-defined.
- . Access to the choice list of IE types for the current
IE.
- Editing of the IE type
- ( / ) Any IE. Any IE can be accepted.
- (0/x) designation. The IE is selected from the choice list.
- (0/x) User defined ie. A type value can be manually entered. The
User defined
ie string is automatically displayed if the type value does not belong to the choice list.
Coding. To edit the content of the current IE according to the
standard encoding fields if any.
Hexa. To edit the content of the current IE if any in
hexadecimal.
then,
Connect data source.
Active source selected for the incoming communication and to be connected if the
IE defined on the same line is present in the SETUP message.
None. (No source is connected) is the only choice.
|