Filter editor: E1 decoding
Selecting
- All. All the conditions are selected.
- None. None of the conditions is selected.
- Alarms from
Network/User. Indications of direction are used as
qualifiers and combined with each condition of alarm type.
No.
There is not any selected conditions on
alarms occurring from the related side.
Yes.
There can be selection of alarms occurring
from the related side, in combination with the conditions.
- Conditions. One condition or several ones can be independently
selected in the list.
No. The condition is not
selected (by default).
Yes. The condition is
selected.
List of conditions
- CRC error. Events reporting a CRC4 error.
- Clock slip. Events reporting a clock slip.
- Alarm modes. Relating to alarm states :
- Current state. To select the events reporting actual states of the
alarm(s) going On or Off.
- Transition. To select the events reporting any transition of the
alarm(s) going On or Off.
- Alarms of Frame type. According to G704 Recommendation :
- FL. Events reporting a loss of frame alignment.
PVT in french.
- ALM. Events reporting an alarm indication to the remote end.
PVTd in french.
- CRC. Events reporting a loss of CRC multi-frame alignment.
- AIS. Events reporting an alarm indication signal (2 Mbits).
SIA in french..
- AIS64K. Events reporting an alarm indication signal (TS 16).
- Sa7 bit. Events reporting the state of the Sa7 bit.
- Alarms of Multiframe type. According to G704 Recommendation :
- MFL. Events reporting a loss of multi-frame alignment (abcd
signalling).
PVMT in french.
- ALM. Events reporting an alarm indication to the remote end
(abcd signalling).
PVMTd in french.
|