IP profile editor: IP Generator
Starting delay. Initial waiting time-period between the
starting of the execution of the profile and the launching of the connection.
An empty field means an infinite value of time.
Execution number. Number of consecutive executions of the connectionon; must have a finite, non-null value.
Delay between exec. Delay between the end of the previous
execution and the launching of the next execution of the connection.
Dest. IP address. Remote IP address.
Call active
Active source. Data source to be connected:
Source selection. For some data source type, a complementary
selection must be done.
Transmission mode. The selected data source is transmitted as a sequence
of datagrams, for a certain number of times, before the connection is stopped.
Datagram length. Size of the convoyed data units built from the active
source of the transmit type in use, if any.
If greater than (IP-MTU)-20, the
fragmentation will be used.
Datagram protocol. An IP Protocol field. A value must be used.
Max transmit rate. Not used.
|