ISDN S0-T0 interface options
Generic options. Options of the Clarinet interface whatever the
emulation mode is.
- Power source 1 monitoring. To monitor the phantom power source.
- Power source 2 monitoring. To monitor the auxiliary power source.
- 100 ohms termination on bus. To connect 100 Ohms terminations on the bus.
- Multi-frame. Multi-frame management (bits Fa and N) defined in
paragraph 6.3 of the I430 recommendation.
- Level 1 measurement. One option must be selected:
- No measurement. no test.
- Send single zeros. Generation of calibrated pulses on the interface (monitoring must be
off).
- Send continuous zeros. Generation of calibrated pulses on the interface (monitoring must be
off).
User specifications. Options to be used if the Clarinet interface emulates a
User side.
- High priority class. To select High Priority Class.
- T3 time-limit. Value of T3 time-limit defined in the I430
recommendation.
If it is equal to 0, the time-limit is not used.
Network specific
options. Options to be used if the Clarinet interface emulates a
Network side.
- Short passive bus. For bus configuration:
- Yes.
Short passive bus mode.
- No.
Self-adapting bus mode.
- Connect power source 1 on bus. To connect the external power source 1 on the bus.
- Invert polarity on power source 1. To invert the polarity of the external power source 1.
|