QSIG signalling behaviour: CommunicationStarting delay. Initial waiting time-period between the
starting of the execution of the profile and the launching of the communication. Execution number. Number of consecutive executions of the communication; must have a finite, non-null value. Delay between exec. Delay between the end of the previous execution and the launching of the next execution of the communication. Call establishment. With the following steps in sequence:
Active state. With the specification of the source to be connected and the duration.
Call clearing. With the following step in sequence:
The Copy QSIG IE buffer and Paste
QSIG IE
buffer functions allow to duplicate
the contents of a particular message to an other one (in the same profile or a different
one).
|
None | No data source connected. | |
Loop | Data echoed TD-RD. | |
Handset | To use the telephone handset (Speaker + Micro) connected to the HANDSET
connector. A Cofidec resource is automatically connected and used. |
|
Analog 1 | Analog Input/Output 1 available on the I/0 connector. A Cofidec resource is automatically connected and used. * Not supported by Clarinet-Book USB type. |
|
Analog 2 | Analog Input/Output 2 available on the I/0 connector. A Cofidec resource is automatically connected and used. * Not supported by Clarinet-Book USB type. |
|
BERT 511 | Bit error rate test - 511 bits pattern. | |
BERT 511+ | Bit error rate test - 511 bits pattern with error counter details. | |
BERT 2047 | Bit error rate test - 2047 bits pattern | |
BERT 2047+ | Bit error rate test - 2047 bits pattern with error counter details. | |
BERT 2**15 | Bit error rate test - 32767 bits pattern. | |
BERT 2**15+ | Bit error rate test - 32767 bits pattern with error counter details. | |
TRANSIT | TRANSIT interface with selection of the used TS's. | |
TRANSDATA | TRANSDATA interface with automatic TS switching from/to the current interface. | |
Data user program | To enable the use of the Data user program as specified in the Data User Program panel. | |
Cofidec 1 | Digital input/output of the Cofidec 1. | |
Cofidec 2 | Digital input/output of the Cofidec 2. | |
Data X25 simulator | To enable the use of the X25 call simulator as specified in the Data Call simulator panel. | |
Byte-TS /Wav | Byte-TS
or wav file selected
from a choice list. 64 Kbits data source (as speech, ...). |
|
Data FR simulator | To enable the use of the Frame Relay call simulator as specified in the Data Call simulator panel. | |
Data IP simulator | To enable the use of the IP call simulator as specified in the Data Call simulator panel. | |
PESQ | Wav file selected
from a choice list (64 Kbits data source). PESQ measurement is carried out on the Tx/Rx data flows at the end of the profile execution according to the following settings:
|
Source selection. For some data source type, a complementary selection area must be accessed.
home Quick start Specifications Connections Features How to? Notes Search Site Map updated: 27-Feb-04 |