ATM signalling behaviour: Communication

Starting delay. Initial waiting time-period between the starting of the execution of the profile and the launching of the communication.
An empty field means an infinite value of time.

Execution number. Number of consecutive executions of the communication; must have a finite, non-null value.

Delay between exec. Delay between the end of the previous execution and the launching of the next execution of the communication.

Call establishment. With the following steps in sequence:

  • User indication. Character string included in a traffic event generated at the beginning of each execution of the communication.
  • Send SETUP... Message transmission.
    Access to editing the attached buffer of IE(s).
  • Send INFORMATION... An optional sequence of INFORMATION messages can be automatically transmitted.

Active state. With the specification of the source to be connected and the duration.

  • Active source. Not used. See ATM VCC usage.
  • Data state duration. If this duration expires, the call is automatically cleared.
    An empty field means an infinite value of time.

Call clearing. With the following step in sequence:

  • Send RELEASE... Message transmission, if the Data state duration expires.
    Access to editing the attached buffer of IE(s).


Copy/Paste functions

The Copy ATM IE  buffer and Paste ATM IE buffer functions allow to duplicate the contents of a particular message to an other one (in the same profile or a different one).

 


home     Quick start     Specifications     Connections     Features     How to?     Notes     Search     Site Map