FR profile editor

Description. The content can be customised to describe briefly the characteristics of the current profile with an ASCII character string.

Min duration. The profile is executed at least during a minimum duration. When this time is over, the profile execution ends when all the incoming or outgoing calls have been ended.
An empty field means an infinite value of time.

Emulation mode. The FR data behaviour of the Clarinet interface.

  • User. Clarinet interface emulates a FR-User side.
  • Network. Clarinet interface emulates a FR-Network side.

Behaviour. Configuration of the simulation.

  • Generator. Specification of the outgoing calls (or connections) of the Call simulator.
  • Responder. Specification of the incoming calls of the Call simulator.
  • Miscellaneous. Specification of various messages to be sent manually, and then initialise the related service.

Configuration. Configuration of the emulators.

  • Layer 2 emulator. Specification of the parameters of the Frame Relay Layer 2 protocol.
  • Layer 3 emulator. Specification of the parameters of the Frame Relay Layer 3 protocol.

Data source definition. To define the characteristics or a list of pre-selected items for each type of data source to be used.

  • Select Transmitted files. To define a list of several file names.
  • Received file. Name of the file which can be used to record received data. File located in the working directory.
    access to the choice list of the files located in the working directory.
  • Transmitted patterns. To define a list of several patterns of characters.
    • Ascii. For editing in ASCII mode.
    • Hexa. For editing in hexadecimal mode.

 