How to simulate one basic call over PRI E1/T1 from the Network side
Simulation of an ISDN terminal is one of the features directly covered
by the templates included in the Clarinet Run-Time.
Connecting the unit
The Clarinet Book USB E1/T1 which simulates the Network
side in front of a User, uses the a port "From
User".
The Clarinet-Book can be connected to the E1 interface in:
The Clarinet-Book can be connected to the T1 interface in:
Creating the profile for PRI-Network simulation
A new profile can be created with the Wizard from the Template list by
selecting:
- Profile->New->ISDN......See: building
- Profile with a description including ISDN, Simu, Network, PH=E1 or
T1, SL=Q931
- Filter with a description including SL= Q931, DL=BOP
Example using the wizard:
- ProfileèNewèISDNèETSIèisdn_etsi_simu_net_e1.acpèFilter?èisdn_etsi_bop.acf
- ProfileèNewèISDNèATT-5ESSèisdn_att_simu_net_t1.acpèFilter?èatt_etsi_bop.acf
Profile resulting from the wizard is ready for monitoring in the D channel
with Q931 decoding
- Modifications to apply to the profile about physical interface:
- E1 Options:
CRC4 multi-frame if CRC4 is used on the interface.
- T1 Options:
ESF/SF multiframing,.....
Saving the profile:
- ProfileèSave
asèfilename.acp.
Running the profile
To launch the profile:
- Select Profile->Run or click over
. It allows to select the name of profile. See Running
a test
- The windows of the Event-Editor is automatically opened.
To stop the profile
- Click over
See: Stopping
a test
- The window of the Event-Editor is automatically close
Troubleshooting over PRI
- No messages displayed on the Event-Editor windows. Check if the Alarms
line have an indication such as ' -+ FL' or '++FL' meaning that no
signal is detected.
- The protocol messages are displayed on the wrong directions: the E1 or T1
pair connected to the A and B port are the reverse side.
- Events "CLOCK SLIP" are displayed by the Event-Editor
periodically: the User side does not synchronize from the Clarinet
interface.
|